Logix |
5 |
20 |
MD |
15 |
W |
1 |
D |
E |
E |
0 |
0 |
0 |
0 |
00 |
0 |
|
AA |
BB |
CC |
D |
E |
F |
G |
H |
I |
J |
K |
L |
MM |
N |
Positioner Model |
Logix |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Standard |
5 |
|
Communication and Diagnostic |
|
|
520 HART - Standard |
20 |
MD |
521 HART - Advanced |
21 |
MD |
522 HART - Pro Diagnostic |
22 |
MD |
|
Certifications |
Intrinsically Safe Class I, Div 1, Groups A,B,C,D (Factory Mutual / CSA) |
-02- |
Nonincendive Class I, Div.2 (FM), Class I, Div.2 (CSA) |
-08- |
General Purpose |
-14- |
Ex ia IIC, ATEX II 1G |
-15- |
|
Housing |
Flowserve: Aluminum, Black with white cover |
W |
Flowserve: Aluminum, Black with yellow cover |
Y |
Flowserve: Aluminum, Black |
D |
|
Threaded Connections |
1/2 NPT conduit, 1/4 NPT pneumatic |
1 |
M20 conduit, 1/4 NPT pneumatic |
2 |
1/2 NPT conduit, 1/4 NPT pneumatic, 1/4 NPT aux. vent |
3 |
M20 conduit, 1/4 NPT pneumatic, 1/4 NPT aux. vent |
4 |
|
Feedback Shaft |
D Shaft - 316SS (Valtek Standard) |
D |
VDI/VDE 3845 (NAMUR) |
R |
|
Temperature |
-40 °C to 85 °C (-40 °F to 185 °F) |
E |
|
Language |
English |
E |
|
Eposition Indicator |
No indicator |
0 |
Flat |
F |
Domed |
D |
|
Special Options |
Standard |
0 |
|
Add-in Electronic Circuits |
None |
0 |
4-20 mA Feedback |
F |
|
Limit Switches |
No switches |
0 |
Mechanical limit switch |
1 |
Reed switch |
2 |
Slot type Namur sensor, P+F NJ2 V3 N |
3 |
Slot type Namur sensor, P+F SJ2 S1N |
4 |
Slot type Namur sensor, P+F SJ2 SN |
5 |
Slot type Namur sensor, P+F SJ2N |
6 |
|
Manifold Options (MM) |
No manifold |
00 |
Double acting |
DA |
Gauge adapter |
GA |
Gauge manifold - NPT Threads |
GM |
Gauge manifold - G Threads |
GC |
VDI/VDE 3847 semi-integrated manifold |
VE |
|
Gauge Options (N) |
DA |
GA |
GM |
|
No gauges |
X |
X |
X |
|
0 |
Output, PSI/BAR/KPA Stainless steel with brass internals |
(qty. 1) |
|
X |
X |
|
1 |
Output + Supply, PSI/BAR/KPA Stainless steel with brass internals |
(qty. 2) |
|
|
X |
|
2 |
Output + Output PSI/BAR/KPA Stainless steel with brass internals |
(qty. 2) |
X |
|
|
|
3 |
Output, PSI/BAR/KPA Stainless steel with stainless steel internals |
(qty. 1) |
|
X |
X |
|
4 |
Output + Supply, PSI/BAR/KPA Stainless steel with stainless steel internals |
(qty. 2) |
|
|
X |
|
5 |
Output + Output, PSI/BAR/KPA Stainless steel with stainless steel internals |
(qty. 2) |
X |
|
|
|
6 |
Output, Kg/Cm2/PSI Stainless steel with brass internals |
(qty. 1) |
|
X |
X |
|
7 |
Output + Supply, Kg/Cm2/PSI Stainless steel with brass internals |
(qty. 2) |
|
|
X |
|
8 |
Output + Output, Kg/Cm2/PSI Stainless steel with brass internals |
(qty. 2) |
X |
|
|
|
9 |
Output, Kg/Cm2/PSI Stainless steel with stainless internals |
(qty. 1) |
|
X |
X |
|
A |
Output + Supply, Kg/Cm2/PSI Stainless steel with stainless steel internals |
(qty. 2) |
|
|
X |
|
B |
Output + Output, Kg/Cm2/PSI Stainless steel with stainless steel internals |
(qty. 2) |
X |
|
|
|
C |
Any KPA gauges |
X |
X |
X |
|
D |
Output + Output + Supply, PSI/BAR/KPA Stainless steel with brass internals |
(qty. 3) |
X |
|
|
|
E |
Output + Output + Supply, PSI/BAR/KPA Stainless with stainless steel internals |
(qty. 3) |
X |
|
|
|
F |
Output + Output + Supply, Kg/Cm2/PSI Stainless steel with brass internals |
(qty. 3) |
X |
|
|
|
G |
Output + Output + Supply, Kg/Cm2/PSI Stainless with stainless steel internals |
(qty. 3) |
|
|
|
|
H |
VE Gauge Options - Consult Factory |
|